last highlighted date: 2023-03-27

Highlights

  • These include basic insulation, functional insulation, altitude, creepage distance, reinforced insulation, double insulation, supplementary insulation, conductive elements, and clearance.
  • With respect to the spacing of the electrical conductor, boards that have a high voltage difference of 80V between the conductors must have these qualities between them. • There should be 0.1 mm between the internal layers • The uncoated external layers must have 0.6 mm in-between them • Also, the uncoated external layers must have about 0.6mm in-between them • Between the coated external layers, there should be 0.13mm in-between them Note that these values are the minimum that these layers ought to have between them.
    • Note: thickness between layers